Non-Contact Proximity & Eddy Current Sensors

Non-Contact Proximity & Eddy Current Sensors

Designed for precise, non-contact measurement of displacement, position, and vibration of metallic components.

Key Features:
Typical Applications:

Get a Quote

Need Technical Assistance?

Our engineering team is ready to support you with product selection, technical consultation and application guidance.

Customer Services

+91 93205 35493

Email

sales@vajrion.com

MNH 10

  • Nominal measuring range: 1 mm to 11 mm
  • Head diameter: 40 mm
  • Dynamic range: up to 10 kHz
  • Operating temperature: Sensor: -30 °C … +180 °C, special versions up to 230°C
  • Protection: IP 67

MNH 2 (BHS)

  • Nominal measuring range: 0,3 mm to 2,3 mm
  • Head diameter: 8 mm
  • Dynamic range: 0 … 5 kHz
  • Operating temperature: Sensor: -40 °C … +200 °C
  • Protection: IP 66

MNH 2 E

  • Nominal measuring range: 0,3 mm to 2,3 mm
  • Head diameter: 8 mm
  • Dynamic range: up to 10 kHz
  • Operating temperature: Sensor: -30 °C … +180 °C, special versions up to 230°C
  • Protection: IP 67

MNH 2 P

  • Nominal measuring range: 0,3 mm to 2,3 mm
  • Head diameter: 8 mm
  • Dynamic range: up to 10 kHz
  • Operating temperature: Sensor: -30 °C … +180 °C, special versions up to 230°C
  • Protection: IP 67

MNH 4

  • Nominal measuring range: 0,5 mm to 4,5 mm
  • Head diameter: 14 mm
  • Dynamic range: up to 10 kHz
  • Operating temperature: Sensor: -30 °C … +180 °C, special versions up to 230°C
  • Protection: IP 67

MNH 8

  • Nominal measuring range: 1 mm to 9 mm
  • Head diameter: 40 mm
  • Dynamic range: up to 10 kHz
  • Operating temperature: Sensor: -30 °C … +180 °C, special versions up to 230°C
  • Protection: IP 67

MNS12-M30

  • Measuring range: 3 mm to 15 mm
  • Output signal: 1 … 9 VDC or 4 … 20 mA
  • Operating temperature: -25 °C … +70 °C
  • Protection: IP 67

MNS2-G6,5

  • Measuring range: 0,5 mm to 2,0 mm
  • Case diameter: 6,5 mm
  • Output signal: 0 … 10 VDC
  • Operating temperature: -25 °C … +70 °C
  • Protection: IP 6

MNS2-M8

  • Measuring range: 0,5 mm to 2,0 mm
  • Output signal: 0 … 10 VDC
  • Operating temperature: -25 °C … +70 °C
  • Protection: IP 67

MNS3-M12

  • Measuring range: 0,25 mm to 3,0 mm
  • Output signal: 1 … 9 VDC oder 4 … 20 mA
  • Operating temperature: -25 °C … +70 °C
  • Protection: IP 67

MNS5-M18

  • Measuring range: 0,5 mm to 5,0 mm
  • Output signal: 1 … 9 VDC oder 4 … 20 mA
  • Operating temperature: -25 °C … +70 °C
  • Protection: IP 67

Connect with Our Experts